The CD-116 is a state-of-the-art digital switchboard designed for military tactical applications requiring integration of voice and data communications. Specifically, the CD-116 enables the integration of a variety of equipment into any field communications system:
Analogue telephones (Local Battery and Common Battery)
Digital terminals (voice and data) and computers
Radio equipment, including Combat Net Radios
Other switchboards, even old magneto type ones
Public networks, both analogue and digital
A highly compact solution provides complete system accessibility through front and rear connectors and binding posts. The Operator Terminal is integrated in the front panel and includes an alphanumeric VF display, a keyboard and the operator handset/headset connector.
The CD-116 fulfils all operational and mechanical requirements of field environment operation. Its small size and low weight, together with its inherent properties for communication readiness, makes it particularly suitable when mobility, reliability and maintainability are at stake.
Up to 60 analogue interfaces for CB, CBS and LB telephones
Up to 4 Radio Interfaces (voice, PTT and squelch)
Up to 4 E&M Interfaces (4 or 6 wires)
Up to 12 CO interfaces for legacy PBX or analogue PSTN
Up to 3 PRI ISDN, G.703 interfaces or Eurocom A/B or C
Up to 6 BRI ISDN Interfaces
Automatic Call Establishment:
Operator Assisted Calls:
Hot Line (fixed destination)
Call Parking
Consultation and Call Swapping
Call Waiting (Camp on), Call Hold and Call Transfer
Call Forwarding
Three Party and Extended Conference Call
Call Priority and Pre-emption
EURO ISDN Services
Built-in self test (BITE) for easy and fast diagnostics
Integrated AC and DC input power supply with automatic switching to battery back up, in case of AC mains failure
| Electrical Specifications | |||
| Power Supply | 90 to 132 VAC (47 – 63 Hz) or | ||
| 180 to 264 VAC (47 - 63 Hz) or | |||
| 21 to 28 VDC | |||
| Consumption | 39 / 47 / 55 W typical (16 / 32 / 48 multifunctional interfaces) | ||
| Multifunctional Interfaces | |||
| Lightning Protection | ITU-T K.11 & K.21 (6 kV) | ||
| Loop resistance (line side) | |||
| CBS mode | 5000 Ω @ 7 mA (off-hook/on-hook detection and pulse dialling) | ||
| CB mode | 1300 Ω @ 20 mA | ||
| Closing voltage (exchange side) | |||
| CBS mode | 4 V @ 7 mA | ||
| CB mode | 5V @ 20 mA | ||
| Ring Current Generator | 60 Vrms 20 Hz ±10%, 2 REN | ||
| Ring Current Detector | 35 Vrms, 10 – 40Hz | ||
| Radio Interfaces | |||
| PTT | 100 mA, 40 Ω | ||
| Squelch | 10 – 60 V, 2.2 kΩ | ||
| E&M Interfaces | 0 or -48 V signalling | ||
| All analogue interfaces | |||
| Insertion loss | ± 1 dB @ 300 – 3400 Hz | ||
| Return loss | 10 dB @ 600 Ω, 300 – 3400 Hz | ||
| Crosstalk | -65 dB @ 300 – 3400 Hz | ||
| Group delay distortion | 1.5 ms @ 300 – 3400 Hz | ||
| Idle noise | -65 dBm0p | ||
| Intermodulation distortion | -40 dB @ 300 – 3400 Hz | ||
| Environmental Specifications | MIL-STD-810F | ||
| Operating temperature | -25 to +70 ºC | ||
| Storage temperature | -40 to +75 ºC | ||
| Humidity | 0 to 95 % | ||
| Watertightness | Method 512.4 | ||
| Shock | Method 516.5 | ||
| Vibration | Method 514.5 | ||
| Physical Specifications | |||
| Dimensions (W x D x H) | 340 x 450 x 193 mm | ||
| Weight | 13.9 / 14.5 / 15.1 Kg typical (16 / 32 / 48 multifunctional interfaces) | ||
| Case color | olive green, RAL 6014 |